THE SYSTEM 2000 FAMILY OF PRODUCTS
EK2, EK3 and FMC EK2 FMC EK3 Frontier EK1, EK2 Frontier EK1 Frontier EK1 Freedom EK1, EK2 EK1, EK2
Energy Star All Energy Kinetics boilers carry the ENERGY STAR® label, although some models may have an efficiency below 85% at increased firing rates. Operations must be at 85% AFUE to qualify as an ENERGY STAR® product.

Click here for more information on AFUE or click here for Tank Specifications.
 
EK1
 
Oil Heat
Gross Output (BTU/hr) 104,000 121,000
AFUE Rating 87.5% 86.2%
  Specifications for oil heat are available in Adobe format.
Illustrated guide: The System 2000 ten-step tune-up for oil heat.
EK1 Frontier
Oil Heat
Natural Gas Heat
Propane
Gross Output (BTU/hr) 104,000 121,000 69,000 85,000 101,000 125,000 70,000 88,000 105,000 129,000
AFUE Rating 87.5% 86.2% 86% 85% 85% 83% 88% 88% 87% 86%
  Specifications for the EK1 Frontier oil heat, natural gas heat and propane are available in Adobe format. Illustrated guide: The System 2000 ten-step tune-up for oil heat, natural gas and propane.
EK1 Freedom Outdoor Boiler
Oil Heat
Natural Gas Heat
Propane
Gross Output (BTU/hr) 104,000 121,000 69,000 85,000 101,000 125,000 70,000 88,000 105,000 129,000
AFUE Rating 87.5% 86.2% 86% 85% 85% 83% 88% 88% 87% 86%
  Specifications for the EK1 Freedom Outdoor Boiler and natural gas heat are available in Adobe format.
EK2
          Oil Heat
Gross Output (BTU/hr) 147,000 170,000 206,000
AFUE Rating 87.6% 87% 84%
  Specifications for oil heat are available in Adobe format.
Illustrated guide: The System 2000 ten-step tune-up for oil heat.

*Larger burner required
EK2 Frontier
Oil Heat
Natural Gas Heat
Propane
Gross Output (BTU/hr) 190,500 206,000 149,500 168,500 187,500 204,500 153,000 173,000 192,000 209,000
AFUE Rating 85.5% 84% 85% 84% 83% 82% 87% 87% 85% 84%
  Specifications for oil heat, natural gas heat and propane are available in Adobe format.
Illustrated guide: The System 2000 ten-step tune-up for oil heat, natural gas and propane.

*Larger burner required
    Weight - only 350 lbs. (shipping weight w/tank and accessories - 550 lbs.)
    Boiler Dimensions - 24-½"L x 24- ¾"W x 27-½"H
    Storage Tank - (115 lbs.) 40 gallon tank standard, up to 120 gallon available
    Domestic Water - 350 gallons per hour (77°F rise in temperature)
EK3 (Oil Heat Only)
 
Oil Heat
Gross Output (BTU/hr) 272,000 313,000 357,000
AFUE Rating 86% 86% 85%
  EK3 Product Data Sheet is available in Adobe format.
    Weight - 650 lbs.
    Boiler Dimensions - 50"L x 33"W x 39 ¾"H (Length front to back includes piping and burner box - the EK3 is designed to fit through a 34" door.)
FMC - The Front-opening Modular Commercial boilers are designed for multiple boiler systems and are available with optional multiple boiler controls. Each FMC boiler is pre-piped and pre-wired and includes single zone heat only operation without energy recovery and full commercial controls with manual reset low water cutoff, manual reset high limit, and National Board Listing. For the product data sheet and firing rates, refer to the EK2 or EK3 and the multiple boiler tables below.

Multiple Boiler Systems for Light Commercial Applications
Number of
EK2 Boilers
FMC or Digital Manager
Gross Output
2 - 3
400 MBTU to 600 MBTU
4 - 5
800 MBTU to 1000 MBTU
6 - 7
1200 MBTU to 1400 MBTU
8 - 9
1600 MBTU to 1800 MBTU
10 - 12
2000 MBTU to 2400 MBTU


Number of
EK3 Boilers
FMC or Digital Manager
Gross Output
2 - 3
700 MBTU to 1070 MBTU
4 - 5
1400 MBTU to 1785 MBTU
6 - 7
2100 MBTU to 2500 MBTU
8 - 9
2800 MBTU to 3200 MBTU
10 - 12
3500 MBTU to 4285 MBTU

Multiple unit installations for light commercial applications are available with schematics upon request.

Glass Lined and Stainless Steel Tanks
All tanks are heavily insulated. Glass lined and stainless steel tanks have a special dip tube to maximize the quality of hot water and most effectively use System 2000 energy recovery.


Standard System 2000 Glass Lined Tanks
 
Diameter
Height
Hot Out, Cold In & Tank Bottom
40 Gallon Standard
20"
48"
¾"
40 Gallon LoBoy
22"
32"
¾"
80 Gallon
24"
60 ½"
¾"
120 Gallon
28"
63 ½"
¾"

Stainless Steel Storage Tanks
 
Diameter
Height
Hot Out, Cold In & Tank Bottom
40 Gallon Stanard
23 ¾"
38"
¾"
75 Gallon
23 ¾"
          65 ½"
¾"

Stainless Steel Indirect
 
Diameter
Height
Hot Out, Cold In & Tank Bottom
Boiler In, Boiler Out
40 Gallon
23 ¾"
38"
¾"
¾"
75 Gallon
23 ¾"
         65 ½"
¾"
¾"


Home Case Studies About our Company Additional Products System 2000 System Benefits Contact Us

*All Energy Kinetics boilers carry the ENERGY STAR® label, although some models may have an efficiency below 85% at increased firing rates. Operation must be above 85% AFUE to qualify as an ENERGY STAR product.

Get Acro Reader
Website Credits
1997-2008
Energy Kinetics, Inc.
The color yellow for heating boilers is a registered trademark for Energy Kinetics.
All rights reserved.
For more information call 1-800-323-2066.