PROUDLY MADE IN THE USA |
| |
As an Energy Star® Partner, Energy Kinetics has determined that this product meets Energy Star® guidelines for energy efficiency. |
|
|
| |
| |
|
|
| |
|
| |
|
|
 |
EK1 69,000 to 129,000 BTU/HR Product Data & Illustrated Tune-up Guide |
|
Specifications: EK1 FRONTIER Front Service |

EK1 Frontier Front Service

EK1 Frontier Stackable
|
| Input |
Gross Output |
AFUE |
Product Sheet |
Tune-up Guide |
| Natural Gas |
69,000 BTU/HR |
86% |

[ View Natural Gas / Propane ]
|
[ View ]
|
| Natural Gas |
85,000 BTU/ HR |
85% |
| Natural Gas |
101,000 BTU/HR |
85% |
| Natural Gas |
125,000 BTU/ HR |
83% |
| Propane |
70,000 BTU/HR |
88% |
| Propane |
88,000 BTU/HR |
88% |
| Propane |
105,000 BTU/HR |
87% |
| Propane |
129,000 BTU/HR |
86% |
| OilHeat |
85,000 BTU/HR |
87.9% |

[ View Oil Heat ]
|
[ View ]
|
| OilHeat |
90,000 BTU/HR |
87.7% |
| OilHeat |
104,000 BTU/HR |
87.5% |
| OilHeat |
121,000 BTU/HR |
86.2% |
EK1 Energy Converter Total Weight: 270 lbs.
EK1 Total System Weight 450 lbs.
EK1 Dimensions: 24.5"L x 17.5"W x 26.5"H
EK1 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK1 Domestic Water: 195 gal/per hour (77ºF rise in temperature)
|
 |
|
Specifications: EK1 Rear Service |

EK1 Rear Service For low clearance and crawl space applications
|
| Input |
Gross Output |
AFUE |
Product Sheet |
Tune-up Guide |
| OilHeat |
104,000 BTU/HR |
87.5% |

[ View Oil Heat ]
|
[ View ]
|
| OilHeat |
121,000 BTU/HR |
86.2% |
EK1 Energy Converter Total Weight: 270 lbs.
EK1 Total System Weight 450 lbs.
EK1 Dimensions: 24.5"L x 17.5"W x 26.5"H
EK1 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK1 Domestic Water: 195 gal/per hour (77ºF rise in temperature)
|
| |
|
|
 |
EK2 149,500 to 209,000 BTU/HR Product Data & Illustrated Tune-up Guide |
|
Specifications: EK2 FRONTIER Front Service |

EK2 FRONTIER Front Service

EK2 Frontier Stackable
|
| Input |
Gross Output |
AFUE |
Product Sheet |
Tune-up Guide |
| Natural Gas |
149,500 BTU/HR |
85% |

[ View Natural Gas / Propane ]
|
[ View ]
|
| Natural Gas |
168,500 BTU/HR |
84% |
| Natural Gas |
187,500 BTU/HR |
83% |
| Natural Gas |
204,500 BTU/HR |
82% |
| Propane |
153,000 BTU/HR |
87% |
| Propane |
173,000 BTU/HR |
87% |
| Propane |
192,000 BTU/HR |
85% |
| Propane |
209,000 BTU/HR |
84% |
| OilHeat |
149,500 BTU/HR |
87.5% |

[ View Oil Heat ]
|
[ View ]
|
| OilHeat |
175,000 BTU/HR |
87.0% |
| OilHeat |
190,000 BTU/HR |
85.5% |
| OilHeat |
206,000 BTU/HR |
84.0% |
EK2 Energy Converter Total Weight: 350 lbs.
EK2 Total System Weight 550 lbs.
EK2 Dimensions: 24.5"L x 24.75"W x 27.5"H
EK2 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK2 Domestic Water: 350 gal/per hour (77ºF rise in temperature)
|
 |
|
Specifications: EK2 Rear Service |

EK2 FRONTIER Rear Service
|
| Input |
Gross Output |
AFUE |
Product Sheet |
Tune-up Guide |
| OilHeat |
147,500 BTU/HR |
87.6% |

[ View Oil Heat ]
|
[ View ]
|
| OilHeat |
170,000 BTU/HR |
87.0% |
| OilHeat |
206,000 BTU/HR |
84.0% |
EK2 Energy Converter Total Weight: 350 lbs.
EK2 Total System Weight 550 lbs.
EK2 Dimensions: 24.5L" x 24.75"W x 27.5"H
EK2 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK2 Domestic Water: 350 gal/per hour (77ºF rise in temperature)
|
| |
|
|
 |
EK3 Up to 357,000 BTU/HR Gross Output Product Data & Illustrated Tune-up Guide |
| | Specifications: EK3 Natural Gas, Propane & Oilheat |

EK3 FRONTIER Front Service
|
| Input |
Gross Output |
AFUE |
Product Sheet |
Tune-up Guide |
| Natural Gas |
255,000 BTU/HR |
85% |

[ View Natural Gas / Propane ]
|
Coming Soon!
|
| Natural Gas |
292,000 BTU/HR |
| Natural Gas |
125,000 BTU/HR |
| Propane |
260,000 BTU/HR |
82% |
| Propane |
299,000 BTU/HR |
| Propane |
335,000 BTU/HR |
| OilHeat |
272,000 BTU/HR |
86.0% |

[ View Oil Heat ]
|
Coming Soon!
|
| OilHeat |
313,000 BTU/HR |
| OilHeat |
357,000 BTU/HR |
EK3 Total System Weight 650 lbs.
EK3 Dimensions: 50"L x 33"W x 39.75"H
Length front to back includes piping and burner box.
The EK3 is designed to fit thru a 34" doorway
|
| |
|
|
 |
Commercial Multiple Boiler Systems Product Data |

Commercial Multiple Boiler Systems
|
Specifications: Commercial Multiple Boiler Systems
Boiler arrays are designed with EK2 or EK3 boilers, and are available with multiple boiler controls which stage fire in response to the heat load and optional distribution system Energy Recovery Controls (ERC). Each boiler is pre-piped and pre-wired; commerical controls include a manual reset low water cutoff, manual reset high limit, and National Board Listing. For product data and firing rates, refer to the EK2 and EK3 data sheets, and the multiple boiler tables below.
|
| |
| EK2 Boilers |
Gross Output |
| 2-3 Boilers |
400 MBTU/HR to 600 MBTU/HR |
| 4-5 Boilers |
800 MBTU/HR to 1000 MBTU/HR |
| 6-7 Boilers |
1200 MBTU/HR to 1400 MBTU/HR |
| 8-9 Boilers |
1600 MBTU/HR to 1800 MBTU/HR |
| 10-12 Boilers |
2000 MBTU/HR to 2400 MBTU/HR |
| EK3 Boilers |
Gross Output |
| 2-3 Boilers |
700 MBTU/HR to 1070 MBTU/HR |
| 4-5 Boilers |
1400 MBTU/HR to 1785 MBTU/HR |
| 6-7 Boilers |
2100 MBTU/HR to 2500 MBTU/HR |
| 8-9 Boilers |
2800 MBTU/HR to 3200 MBTU/HR |
| 10-12 Boilers |
3500 MBTU/HR to 4285 MBTU/HR |
Multiple unit installations for commercial applications are available with schematics upon request.
|
|