Find a Heating Expert Near You
On this page:
Tune-up guides
EK1 Frontier
EK2 Frontier
EK3
Commercial multiple
   boiler systems

Saves more than other boilers:
Calculate my savings!
Dept. of Energy lab results
Proven reliability
  and performance

Virtually endless hot showers
Whisper quiet operation

Contact us
View System 2000 Brochure View System 2000 Video
View System 2000 Brochure View System 2000 Video
View System 2000 Brochure View System 2000 Video
VIEW BROCHURE VIEW VIDEO
 
 
   
Products - Tune-up Guides Gallery
   
     
EK1 69,000 to 129,000 BTU/HR
Product Data & Illustrated Tune-up Guide

Specifications: EK1 FRONTIER Front Service
EK1 Frontier - Front Service
EK1 Frontier
Front Service

EK1 Frontier - Stackable
EK1 Frontier
Stackable
Input Gross Output AFUE Product Sheet Tune-up Guide
Natural Gas 69,000 BTU/HR 86%
[ View Natural Gas / Propane ]
View Illustrated Tune-up Guide
[ View ]
Natural Gas 85,000 BTU/ HR 85%
Natural Gas 101,000 BTU/HR 85%
Natural Gas 125,000 BTU/ HR 83%
Propane 70,000 BTU/HR 88%
Propane 88,000 BTU/HR 88%
Propane 105,000 BTU/HR 87%
Propane 129,000 BTU/HR 86%
OilHeat 85,000 BTU/HR 87.9%
[ View Oil Heat ]
View Illustrated Tune-up Guide
[ View ]
OilHeat 90,000 BTU/HR 87.7%
OilHeat 104,000 BTU/HR 87.5%
OilHeat 121,000 BTU/HR 86.2%

EK1 Energy Converter Total Weight: 270 lbs.
EK1 Total System Weight 450 lbs.
EK1 Dimensions: 24.5"L x 17.5"W x 26.5"H
EK1 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK1 Domestic Water: 195 gal/per hour (77║F rise in temperature)


Specifications: EK1 Rear Service
EK1 - Rear Service
EK1
Rear Service
For low clearance
and crawl space
applications

Input Gross Output AFUE Product Sheet Tune-up Guide
OilHeat 104,000 BTU/HR 87.5%
[ View Oil Heat ]
View Illustrated Tune-up Guide
[ View ]
OilHeat 121,000 BTU/HR 86.2%

EK1 Energy Converter Total Weight: 270 lbs.
EK1 Total System Weight 450 lbs.
EK1 Dimensions: 24.5"L x 17.5"W x 26.5"H
EK1 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK1 Domestic Water: 195 gal/per hour (77°F rise in temperature)
     
EK2 149,500 to 209,000 BTU/HR
Product Data & Illustrated Tune-up Guide

Specifications: EK2 FRONTIER Front Service
EK2 FRONTIER Front Service
EK2 FRONTIER
Front Service
EK2 Frontier - Stackable
EK2 Frontier
Stackable
Input Gross Output AFUE Product Sheet Tune-up Guide
Natural Gas 149,500 BTU/HR 85%
[ View Natural Gas / Propane ]
View Illustrated Tune-up Guide
[ View ]
Natural Gas 168,500 BTU/HR 84%
Natural Gas 187,500 BTU/HR 83%
Natural Gas 204,500 BTU/HR 82%
Propane 153,000 BTU/HR 87%
Propane 173,000 BTU/HR 87%
Propane 192,000 BTU/HR 85%
Propane 209,000 BTU/HR 84%
OilHeat 149,500 BTU/HR 87.5%
[ View Oil Heat ]
View Illustrated Tune-up Guide
[ View ]
OilHeat 175,000 BTU/HR 87.0%
OilHeat 190,000 BTU/HR 85.5%
OilHeat 206,000 BTU/HR 84.0%

EK2 Energy Converter Total Weight: 350 lbs.
EK2 Total System Weight 550 lbs.
EK2 Dimensions: 24.5"L x 24.75"W x 27.5"H
EK2 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK2 Domestic Water: 350 gal/per hour (77°F rise in temperature)


Specifications: EK2 Rear Service
EK2 FRONTIER Rear Service
EK2 FRONTIER
Rear Service
Input Gross Output AFUE Product Sheet Tune-up Guide
OilHeat 147,500 BTU/HR 87.6%
[ View Oil Heat ]
View Illustrated Tune-up Guide
[ View ]
OilHeat 170,000 BTU/HR 87.0%
OilHeat 206,000 BTU/HR 84.0%

EK2 Energy Converter Total Weight: 350 lbs.
EK2 Total System Weight 550 lbs.
EK2 Dimensions: 24.5L" x 24.75"W x 27.5"H
EK2 Storage Tank: 115 lbs. 40 gal standard, up to 120 gal available
EK2 Domestic Water: 350 gal/per hour (77°F rise in temperature)
     
EK3 Up to 357,000 BTU/HR Gross Output
Product Data & Illustrated Tune-up Guide

 Specifications: EK3 Natural Gas, Propane & Oilheat
EK3 FRONTIER Front Service
EK3 FRONTIER
Front Service
Input Gross Output AFUE Product Sheet Tune-up Guide
Natural Gas 255,000 BTU/HR 85%
[ View Natural Gas / Propane ]
Coming Soon!
Natural Gas 292,000 BTU/HR
Natural Gas 125,000 BTU/HR
Propane 260,000 BTU/HR 82%
Propane 299,000 BTU/HR
Propane 335,000 BTU/HR
OilHeat 272,000 BTU/HR 86.0%
[ View Oil Heat ]
Coming Soon!
OilHeat 313,000 BTU/HR
OilHeat 357,000 BTU/HR

EK3 Total System Weight 650 lbs.
EK3 Dimensions: 50"L x 33"W x 39.75"H
Length front to back includes piping and burner box.
The EK3 is designed to fit thru a 34" doorway

     
Commercial Multiple Boiler Systems
Product Data


Commercial Multiple Boiler Systems
Commercial Multiple
Boiler Systems
Specifications: Commercial Multiple Boiler Systems
Boiler arrays are designed with EK2 or EK3 boilers, and are available with multiple boiler controls which stage fire in response to the heat load and optional distribution system Energy Recovery Controls (ERC). Each boiler is pre-piped and pre-wired; commerical controls include a manual reset low water cutoff, manual reset high limit, and National Board Listing. For product data and firing rates, refer to the EK2 and EK3 data sheets, and the multiple boiler tables below.
 
EK2 Boilers Gross Output
2-3 Boilers 400 MBTU/HR to 600 MBTU/HR
4-5 Boilers 800 MBTU/HR to 1000 MBTU/HR
6-7 Boilers 1200 MBTU/HR to 1400 MBTU/HR
8-9 Boilers 1600 MBTU/HR to 1800 MBTU/HR
10-12 Boilers 2000 MBTU/HR to 2400 MBTU/HR


EK3 Boilers Gross Output
2-3 Boilers 700 MBTU/HR to 1070 MBTU/HR
4-5 Boilers 1400 MBTU/HR to 1785 MBTU/HR
6-7 Boilers 2100 MBTU/HR to 2500 MBTU/HR
8-9 Boilers 2800 MBTU/HR to 3200 MBTU/HR
10-12 Boilers 3500 MBTU/HR to 4285 MBTU/HR


Multiple unit installations for commercial applications are available with schematics upon request.



[ Back To Top

ENERGY STAR Partner Hand Crafted By Americans For American Homes
Energy Kinetics Energy Kinetics